Assignment error: Overwriting of a protected field.
Updated May 18, 2018
Runtime Errors: MOVE TO LIT NOTALLOWED NODATA
Hello SAP Experts,
After modification in SAP ERP Central Component (ECC) while reimporting of the Classification DataSource (1CL_*) fails in SAP Data Services 4.2. On Backend side the running process dumps in CL_SQL_RESULT_SET=>NEXT_PACKAGE .
Runtime Errors:
MOVE_TO_LIT_NOTALLOWED_NODATA
A short text is also generated:
Regenerating Error
The issue can be regenerated by trying to reimport it to SAP Data Services 4.2 after modifying structure of a Classification DataSource (1CL_*) in SAP ERP Central Component (ECC) system.
The error you are facing is caused because the method CLASS_CONSTRUCTOR of the class CL_RODPS_HANA_MODEL executes several unnecessary SQL statements while reimporting.
Please apply SAP Document 2111563 in order to resolve this error
- Search
Search Results
- Natural for Mainframes 8.2.8
- Parameter Reference
OPF - Overwriting of Protected Fields by Helproutines
This Natural profile and session parameter specifies whether the content of a write-protected field (attribute definition AD =P ) can be overwritten by a helproutine assigned to the field.
- The OPF profile parameter only applies to the field for which a helproutine is invoked; it does not affect parameters explicitly passed to the helproutine. This means that the OPF profile parameter takes no effect if the field for which help is invoked is also explicitly specified as a parameter to be passed to the helproutine.
- In addition, in reporting mode you can change the OPF setting using the statement SET GLOBALS .
- Within a Natural session, the profile parameter OPF can be overridden by the session parameter OPF .
3028865 - Dump MOVE_TO_LIT_NOTALLOWED_NODATA is SAP Solution Manager 7.2
ST22 the following dump is prodcued
Runtime Errors MOVE_TO_LIT_NOTALLOWED_NODATA Short Text
Assignment error: Overwriting of a protected field.
What happened? Error in the ABAP Application Program
The current ABAP program "SAPLAGSDVMAS_SELF_SERVICE" had to be terminated because it has come across a statement that unfortunately cannot be executed.
>>>> CONDENSE <ls_errors>-parameter1
Environment
SAP Solution Manager 7.2 SP08 - SP12
MOVE_TO_LIT_NOTALLOWED_NODATA, runtime error, dvm, ewa, SAPLAGSDVMAS_SELF_SERVICE , KBA , SV-SMG-DVM , Data Volume Management , Problem
About this page
Search for additional results.
Visit SAP Support Portal's SAP Notes and KBA Search .
Privacy | Terms of use | Legal Disclosure | Copyright | Trademark
IMAGES
VIDEO
COMMENTS
how to pass the values to read only field in the structure of the field symbol. my field symbol is a structure has 6 fields, i can pass values to all fields except one which has read only checked. if i pass value to that field dumb is coming. ASSIGN COMPONENT 'STYLE3' OF STRUCTURE <fs_Wax10> TO <fs_Wax8>. <fs_Wax8> = SPACE.
Newbie question, sorry. Option 1: Use an abstract Property and override it on the inherited classes. This benefits from being enforced (you have to override it) and it is clean. But, it feels slightly wrong to return a hard-code value rather than encapsulate a field and it is a few lines of code instead of just.
Hi, I'm having an error message when the program dumps: Assignment error: Overwriting a protected field. And it is pointed in this code: 012370 DATA: 012380 up_field ...
Hi, I am using the FM UPF_EXIT_CREATE_ENTRY_01 to add a new entry to the buffer. The error I am getting is "Assignment error: Overwriting a protected field" and it is ...
"CL_FPM_FORM_UIBB_ASSIST=====CP", in "GET_CONFIGURED_FIELDS". The main program was "SAPMHTTP". Source Code Extract: IF NOT iv_name IS INITIAL. READ TABLE mt_config_fields TRANSPORTING NO FIELDS WITH TABLE KEY component = iv_name. IF sy-subrc <> 0. RETURN. ENDIF. APPEND INITIAL LINE TO et_field ASSIGNING FIELD-SYMBOL(<field>). >>>>> <field>-name ...
Join the discussions or start your own on all things application development, including tools and APIs, programming models, and keeping your skills sharp.
Assignment error: Overwriting of a protected field:After modification in SAP ERP Central Component (ECC) while reimporting of the Classification DataSource (1CL_*) fails in SAP Data Services 4.2. ... Assignment error: Overwriting of a protected field:After modification in SAP ERP Central Component (ECC) while reimporting of the Classification ...
Assignment error: Overwriting of a protected field. ... 37 ID 'CONNAME' FIELD me->con_ref->con_name 38 ID 'CONDA' FIELD me->con_ref->con_da 39 ID 'CURSOR' FIELD me->cursor 40 ID 'BOUND' FIELD me->outvals_bound ...
This Natural profile and session parameter specifies whether the content of a write-protected field (attribute definition AD=P) can be overwritten by a helproutine assigned to the field. A helproutine assigned to a field can overwrite the field's content, even if the field is write-protected. Helproutines cannot overwrite the contents of write ...
MOVE_TO_LIT_NOTALLOWED_NODATA, runtime error, dvm, ewa, SAPLAGSDVMAS_SELF_SERVICE , KBA , SV-SMG-DVM , Data Volume Management , Problem About this page This is a preview of a SAP Knowledge Base Article.
حل مشكلة RFC ERORR: Assignment error: Overwriting of a protected field undefinedعند إعداد وتقديم إقرار ضريبة القيمة المضافة أو نموذج ٤١ خصم ...